Security Advice · Paradox Alarms

Why Is My Paradox Alarm Beeping? Trouble Codes Explained

A Paradox keypad that beeps every few seconds is not broken. It is telling you it has found a problem, and it will keep telling you until the problem is fixed. Here is how to see what it is, what each trouble number means, and the one you can sort out yourself.

The short answer

  • Press the [TBL] (trouble) key. That stops the beeping and lights up a number on the keypad. The number tells you what the panel has found.
  • After a power cut, it is usually trouble 8 (timer loss). The clock needs setting again, and that is the one trouble Paradox says owners should fix themselves.
  • Trouble 2 is power: mains off, or a backup battery that is flat or worn out. Paradox recommends a new battery every three years.
  • Trouble 4 is communication. Since New Zealand switched off 3G in March 2026, and copper lines are being retired, this is now common on older systems.
  • Silencing the beep does not clear the fault. If the light stays on, the panel still has a problem.

First: is it a trouble beep, or the alarm?

If the siren is going or the keypad is beeping fast and continuously, the alarm has been triggered. Enter your code to disarm it. That is a different situation from the one this article is about.

A trouble beep is a short beep every few seconds, with the [TBL] or trouble light on. The system is still working, but the panel has found something wrong with itself: power, a battery, a detector, a tamper switch or the way it reports. Your installer can change how it beeps, so some systems only show the light.

How to see the trouble code

On Spectra SP and Magellan (MG) keypads, press [TBL]. The beeping stops and one or more numbers light up. Each lit number is a separate trouble. Press [CLEAR] to go back to normal.

Keypads with a text screen show the trouble in words instead. On an EVO system, press [TRBL], or on a K656 touch keypad open the menu and choose View Trouble. The EVO groups are slightly different and are listed further down.

Write the numbers down before you do anything else. If you call us, they save half the diagnosis.

Paradox trouble codes (Spectra SP and Magellan)

Number What it means What usually fixes it
1 A wireless detector’s battery is low New battery in that detector
2 Power: mains failure, or the panel’s backup battery is low or missing Check the power. If mains is fine, the battery is due
3 Siren (bell) disconnected or overloaded Siren or wiring fault, needs a technician
4 Communication: cannot reach the phone line, monitoring centre, cellular or internet Often a dead copper line or an old 3G unit
5 Tamper, or a fault in a zone’s wiring A cover left open, or a damaged cable
6 Tamper on a module (keypad, expander, wireless receiver, siren) A housing not closed properly
7 Fire loop trouble Smoke detector circuit fault, needs a technician
8 Timer loss: the clock has stopped Set the time and date (see below)
9 A wireless detector has stopped checking in Flat battery, or a moved or failed detector
10 A module has stopped checking in (keypad, expander, internet or cellular module) Wiring or a failed module

Some keypads also light 16 or the SLEEP key to show a fault with the keypad itself. Most of these numbers have sub-codes. An installer can read them from the panel to narrow it down, for example which zone or which battery.

Trouble 8 after a power cut: the one you can fix

If the power has been off long enough for the backup battery to run down, the panel loses track of the time. When the power comes back it lights trouble 8 and beeps. Nothing is wrong with the system. It just needs the clock set.

On most Spectra SP and Magellan keypads, Paradox’s user guide gives this sequence:

  • Press the action key (the one with the power symbol), then enter your master code.
  • Press [TBL], then [5].
  • Enter the time as hours and minutes (HH:MM), then choose 1 for 24-hour, 2 for AM or 3 for PM.
  • Enter the date as year, month, day (YYYY/MM/DD), then press [CLEAR] to finish.

Keypads vary, and some older ones take 24-hour time only. If yours does not respond to that sequence, or you do not have the master code, it is a quick job for us. If trouble 8 keeps coming back after short power cuts, the backup battery is not holding a charge. That is trouble 2, below.

Trouble 2: power or the backup battery

Trouble 2 covers two different things. If the mains power to the panel is off, check whether the house has power and whether the plug pack or circuit that feeds the alarm is on. Once mains is back, the trouble should clear by itself.

If the mains is fine and trouble 2 stays on, it is almost always the backup battery: a 12 V sealed lead-acid battery inside the panel. After a long power cut a healthy battery recharges within a day or so. One that does not is worn out. Paradox recommends replacing it every three years, and most of the beeping systems we are called to have a battery much older than that.

If you are not comfortable opening the panel, it is a quick job at a service, and we test the rest of the system while we are there. See alarm servicing and repairs.

Trouble 1 and 9: a wireless detector

If your system has wireless detectors, door contacts or remotes, each one has its own battery. Trouble 1 means one of them is running low. Paradox’s wireless motion detectors and remotes typically run about two years on a set, less in a busy room. The keypad or an installer can tell you which zone it is.

Trouble 9 means a wireless detector has stopped checking in with the panel altogether. Usually the battery has gone completely flat. Sometimes the detector has been knocked, moved too far away, or has failed. Do not ignore it: that detector is not protecting anything until it is fixed.

Trouble 4: it cannot report (copper and 3G)

Trouble 4 means the panel tried to send a message and could not. On older systems in Auckland, the usual cause has changed in the last year. Every New Zealand 3G network was switched off by the end of March 2026, and Chorus is retiring copper phone lines in fibre areas by the end of 2026. An alarm that reports through a 3G unit or a copper line has lost that path.

That matters most if you pay for monitoring: the control room may not be getting your alarms at all. The fix is a new communicator, either a 4G unit or an internet module, and on most Paradox panels that is an upgrade to the existing system, not a new alarm. If you do not have monitoring, the panel may still be programmed to dial a phone line that is no longer there. Reprogramming it stops the beeping.

Not sure if your monitoring is still getting through? Ask your monitoring company for a test, or see alarm monitoring.

On an EVO panel

EVO48, EVO96 and EVO192 systems group their troubles differently. The main groups are:

Group Covers
1 System Mains failure, battery, siren and auxiliary power faults
2 Communicator Phone line, and failure to reach the monitoring centre
3 Module A module’s tamper, power, battery or communication
4 Network A keypad or module missing from the bus
5 Zone tamper A detector or its cable tampered with
6 Zone low battery A wireless device running low
7 Zone fault Communication, fire loop or a dirty smoke detector
8 Clock loss Press 8 to set the time again
9 GSM / 10 IP The cellular or internet module

When to call someone

Set the clock yourself for trouble 8. Change a remote’s battery if you are confident. For anything else, and especially for trouble 3, 4, 5, 7 or 10, it needs testing: they point at wiring, sirens, fire circuits or reporting, and guessing wastes your time.

We service and repair Paradox systems across Auckland, including ones we did not install. Send us the trouble numbers and a photo of the keypad and panel label, and we will usually know what to bring. See alarm repairs in Auckland or Paradox alarms in Auckland.

Common questions

Why is my Paradox alarm beeping?

A short beep every few seconds is a trouble beep. The panel has found a fault such as a power cut, a flat backup battery, a low wireless detector battery or a lost phone line. Press [TBL] to see which trouble number is lit.

How do I stop my Paradox alarm beeping?

Press the [TBL] key. That silences the trouble beep and shows the trouble number. The fault is still there until it is fixed, so the light stays on and the beep can come back.

Why is my alarm beeping after a power cut?

Usually trouble 8, timer loss: the clock stopped while the power was off and needs setting again. If trouble 2 is also lit, the backup battery may be flat or worn out.

What is trouble 8 on a Paradox alarm?

Timer loss. The panel’s clock has stopped, normally after a power cut that ran the backup battery down. Set the time and date from the keypad with your master code.

How often should a Paradox alarm battery be replaced?

Paradox recommends replacing the panel’s backup battery every three years. Wireless detectors and remotes have their own batteries, which typically last about two years.

Can you fix a Paradox alarm you did not install?

Yes. We service and repair Paradox systems across Auckland whoever installed them. Send us the trouble numbers and a photo of the keypad, and we can usually tell you what it needs before we visit.

Paradox alarm still beeping?

Send us the trouble numbers. We will tell you what it is likely to be and give you a fixed price before any repair starts.

Get a Free Quote022 538 3587